MWPowerPlantFacts

Data last collected:

EIA plant 7277

Stanley · Lincoln · NC

Lincoln Combustion

Operated by Duke Energy Carolinas, LLC

Annual generation3,843 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextDuke Energy CarolinasBalancing authority or NERC region

Published location

Where is Lincoln Combustion?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

35.431700, -81.034700

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combustion Turbine2,290 MW represented

Grouped from this plant’s represented generator records. Use the NC plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1-452
2-296
3-810
4-634
5-728
6-669
73,855
81,447
9586
100
112,503
12-959

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1-452
2-296
3-810
4-634
5-728
6-669
73,855
81,447
9586
100
112,503
12-959

2024 monthly net generation

MonthNet generation
1-452 MWh
2-296 MWh
3-810 MWh
4-634 MWh
5-728 MWh
6-669 MWh
73,855 MWh
81,447 MWh
9586 MWh
100 MWh
112,503 MWh
12-959 MWh

Operating generators

IDTechnologyFuelMWStatus
17Natural Gas Fired Combustion TurbineNG536.4OP
1Natural Gas Fired Combustion TurbineNG109.6OP
10Natural Gas Fired Combustion TurbineNG109.6OP
11Natural Gas Fired Combustion TurbineNG109.6OP
12Natural Gas Fired Combustion TurbineNG109.6OP
13Natural Gas Fired Combustion TurbineNG109.6OP
14Natural Gas Fired Combustion TurbineNG109.6OP
15Natural Gas Fired Combustion TurbineNG109.6OP
16Natural Gas Fired Combustion TurbineNG109.6OP
2Natural Gas Fired Combustion TurbineNG109.6OP
3Natural Gas Fired Combustion TurbineNG109.6OP
4Natural Gas Fired Combustion TurbineNG109.6OP
5Natural Gas Fired Combustion TurbineNG109.6OP
6Natural Gas Fired Combustion TurbineNG109.6OP
7Natural Gas Fired Combustion TurbineNG109.6OP
8Natural Gas Fired Combustion TurbineNG109.6OP
9Natural Gas Fired Combustion TurbineNG109.6OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
7277
Sector
Electric Utility
Water source
Killian Creek
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Lincoln Combustion power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Lincoln Combustion

Variation in the published months

Across 5 numeric monthly generation entries, 7 has the highest recorded value (3,855 MWh) and 10 the lowest (0 MWh). Their difference is 3,855 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 17 numeric rows displayed in this table, MW ranges from 109.6 (1, 10, 11) to 536.4 (17). The difference is 426.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Natural Gas Fired Combustion Turbine109.673.094.073.0
10Natural Gas Fired Combustion Turbine109.673.096.073.0
11Natural Gas Fired Combustion Turbine109.673.095.073.0
12Natural Gas Fired Combustion Turbine109.673.094.073.0
13Natural Gas Fired Combustion Turbine109.672.093.072.0
14Natural Gas Fired Combustion Turbine109.672.094.072.0
15Natural Gas Fired Combustion Turbine109.673.094.073.0
16Natural Gas Fired Combustion Turbine109.673.093.073.0
17Natural Gas Fired Combustion Turbine536.4365.0402.0130.0
2Natural Gas Fired Combustion Turbine109.674.096.074.0
3Natural Gas Fired Combustion Turbine109.673.095.073.0
4Natural Gas Fired Combustion Turbine109.673.094.073.0
5Natural Gas Fired Combustion Turbine109.672.093.072.0
6Natural Gas Fired Combustion Turbine109.672.093.072.0
7Natural Gas Fired Combustion Turbine109.672.095.072.0
8Natural Gas Fired Combustion Turbine109.672.094.072.0
9Natural Gas Fired Combustion Turbine109.671.094.071.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check