MWPowerPlantFacts

Data last collected:

EIA plant 7380

Bowling Green · Hardee · FL

Midulla Generating Station

Operated by Seminole Electric Cooperative Inc

Annual generation2,884,488 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextSeminole Electric CooperativeBalancing authority or NERC region

Published location

Where is Midulla Generating Station?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

27.641667, -81.962500

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle543.3 MW represented
TechnologyNatural Gas Fired Combustion Turbine310 MW represented

Grouped from this plant’s represented generator records. Use the FL plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

113,494
2329,078
3296,506
420,499
5198,602
6344,075
7357,015
8150,854
9326,154
10179,383
11359,020
12309,808

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
113,494
2329,078
3296,506
420,499
5198,602
6344,075
7357,015
8150,854
9326,154
10179,383
11359,020
12309,808

2024 monthly net generation

MonthNet generation
113,494 MWh
2329,078 MWh
3296,506 MWh
420,499 MWh
5198,602 MWh
6344,075 MWh
7357,015 MWh
8150,854 MWh
9326,154 MWh
10179,383 MWh
11359,020 MWh
12309,808 MWh

Operating generators

IDTechnologyFuelMWStatus
CT1Natural Gas Fired Combined CycleNG181.1OP
CT2Natural Gas Fired Combined CycleNG181.1OP
ST3Natural Gas Fired Combined CycleNG181.1OP
GT4Natural Gas Fired Combustion TurbineNG62OP
GT5Natural Gas Fired Combustion TurbineNG62OP
GT6Natural Gas Fired Combustion TurbineNG62OP
GT7Natural Gas Fired Combustion TurbineNG62OP
GT8Natural Gas Fired Combustion TurbineNG62OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
7380
Sector
Electric Utility
Water source
Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Midulla Generating Station power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Midulla Generating Station

Variation in the published months

Across 12 numeric monthly generation entries, 11 has the highest recorded value (359,020 MWh) and 1 the lowest (13,494 MWh). Their difference is 345,526 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 8 numeric rows displayed in this table, MW ranges from 62 (GT4, GT5, GT6) to 181.1 (CT1, CT2, ST3). The difference is 119.1 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT1Natural Gas Fired Combined Cycle181.1179.0198.090.0
CT2Natural Gas Fired Combined Cycle181.1179.0198.090.0
GT4Natural Gas Fired Combustion Turbine62.054.062.014.0
GT5Natural Gas Fired Combustion Turbine62.054.062.014.0
GT6Natural Gas Fired Combustion Turbine62.054.062.014.0
GT7Natural Gas Fired Combustion Turbine62.054.062.014.0
GT8Natural Gas Fired Combustion Turbine62.027.031.014.0
ST3Natural Gas Fired Combined Cycle181.1185.0187.062.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.