MWPowerPlantFacts

Data last collected:

EIA plant 7710

Smiths · Lee · AL

H Allen Franklin Combined Cycle

Operated by Southern Power Co

Annual generation11,738,168 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextSouthern Company Services, Inc. - TransBalancing authority or NERC region

Published location

Where is H Allen Franklin Combined Cycle?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

32.607800, -85.097500

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle1,995.7 MW represented

Grouped from this plant’s represented generator records. Use the AL plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,164,909
2948,377
3661,230
4714,036
5747,294
61,043,192
71,232,792
81,195,235
9989,387
10807,336
111,111,572
121,122,808

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,164,909
2948,377
3661,230
4714,036
5747,294
61,043,192
71,232,792
81,195,235
9989,387
10807,336
111,111,572
121,122,808

2024 monthly net generation

MonthNet generation
11,164,909 MWh
2948,377 MWh
3661,230 MWh
4714,036 MWh
5747,294 MWh
61,043,192 MWh
71,232,792 MWh
81,195,235 MWh
9989,387 MWh
10807,336 MWh
111,111,572 MWh
121,122,808 MWh

Operating generators

IDTechnologyFuelMWStatus
ST2Natural Gas Fired Combined CycleNG281.9OP
ST3Natural Gas Fired Combined CycleNG281.9OP
ST1Natural Gas Fired Combined CycleNG213.3OP
CT1ANatural Gas Fired Combined CycleNG203.1OP
CT1BNatural Gas Fired Combined CycleNG203.1OP
CT2ANatural Gas Fired Combined CycleNG203.1OP
CT2BNatural Gas Fired Combined CycleNG203.1OP
CT3ANatural Gas Fired Combined CycleNG203.1OP
CT3BNatural Gas Fired Combined CycleNG203.1OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
7710
Sector
IPP Non-CHP
Water source
Chattahoochee River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right H Allen Franklin Combined Cycle power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at H Allen Franklin Combined Cycle

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (1,232,792 MWh) and 3 the lowest (661,230 MWh). Their difference is 571,562 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 9 numeric rows displayed in this table, MW ranges from 203.1 (CT1A, CT1B, CT2A) to 281.9 (ST2, ST3). The difference is 78.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT1ANatural Gas Fired Combined Cycle203.1177.5188.5115.0
CT1BNatural Gas Fired Combined Cycle203.1177.5188.5115.0
CT2ANatural Gas Fired Combined Cycle203.1177.8190.3125.0
CT2BNatural Gas Fired Combined Cycle203.1177.8190.3125.0
CT3ANatural Gas Fired Combined Cycle203.1182.6196.6109.0
CT3BNatural Gas Fired Combined Cycle203.1182.6196.6109.0
ST1Natural Gas Fired Combined Cycle213.3240.0240.0120.0
ST2Natural Gas Fired Combined Cycle281.9293.0293.0130.0
ST3Natural Gas Fired Combined Cycle281.9293.0293.0112.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research