MWPowerPlantFacts

Data last collected:

EIA plant 10521

Pearl River · Rockland · NY

Lederle Laboratories

Operated by Veolia NA - Municipal & Commercial Business

Annual generation149,752 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextNew York Independent System OperatorBalancing authority or NERC region

Published location

Where is Lederle Laboratories?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

41.077200, -74.018100

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle23.4 MW represented

Grouped from this plant’s represented generator records. Use the NY plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

115,680.05
213,671.18
313,063.96
48,386.62
512,790.42
612,157.98
713,050.38
813,354.96
911,534.27
109,028.76
1113,587.76
1213,445.17

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
115,680.05
213,671.18
313,063.96
48,386.62
512,790.42
612,157.98
713,050.38
813,354.96
911,534.27
109,028.76
1113,587.76
1213,445.17

2024 monthly net generation

MonthNet generation
115,680 MWh
213,671 MWh
313,064 MWh
48,387 MWh
512,790 MWh
612,158 MWh
713,050 MWh
813,355 MWh
911,534 MWh
109,029 MWh
1113,588 MWh
1213,445 MWh

Operating generators

IDTechnologyFuelMWStatus
GEN1Natural Gas Fired Combined CycleNG8.3OP
GEN2Natural Gas Fired Combined CycleNG8.3OP
TG4Natural Gas Fired Combined CycleNG3.1OP
GEN3Natural Gas Fired Combined CycleNG2.2OP
3ANatural Gas Fired Combined CycleNG1.5OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
10521
Sector
Industrial CHP
Water source
Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Lederle Laboratories power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Lederle Laboratories

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (15,680 MWh) and 4 the lowest (8,387 MWh). Their difference is 7,293 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 5 numeric rows displayed in this table, MW ranges from 1.5 (3A) to 8.3 (GEN1, GEN2). The difference is 6.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
3ANatural Gas Fired Combined Cycle1.51.51.50.1
GEN1Natural Gas Fired Combined Cycle8.38.38.34.5
GEN2Natural Gas Fired Combined Cycle8.38.38.34.5
GEN3Natural Gas Fired Combined Cycle2.22.22.20.1
TG4Natural Gas Fired Combined Cycle3.11.41.40.1

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check