MWPowerPlantFacts

Data last collected:

EIA plant 3403

Gallatin · Sumner · TN

Gallatin (TN)

Operated by Tennessee Valley Authority

Annual generation4,158,220 MWhSum of represented EIA-923 rows
Fuel codesBIT, SUB, NGCodes retained from EIA records
Grid contextTennessee Valley AuthorityBalancing authority or NERC region

Published location

Where is Gallatin (TN)?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

36.315600, -86.400600

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Steam Coal1,255.2 MW represented
TechnologyNatural Gas Fired Combustion Turbine663.2 MW represented

Grouped from this plant’s represented generator records. Use the TN plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1463,415
2240,164
3146,891
4135,955
5202,864
6342,280
7457,910
8499,496
9504,938
10494,499
11252,888
12416,920

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1463,415
2240,164
3146,891
4135,955
5202,864
6342,280
7457,910
8499,496
9504,938
10494,499
11252,888
12416,920

2024 monthly net generation

MonthNet generation
1463,415 MWh
2240,164 MWh
3146,891 MWh
4135,955 MWh
5202,864 MWh
6342,280 MWh
7457,910 MWh
8499,496 MWh
9504,938 MWh
10494,499 MWh
11252,888 MWh
12416,920 MWh

Operating generators

IDTechnologyFuelMWStatus
3Conventional Steam CoalSUB327.6OP
4Conventional Steam CoalSUB327.6OP
1Conventional Steam CoalBIT300OP
2Conventional Steam CoalSUB300OP
GT5Natural Gas Fired Combustion TurbineNG84.5OP
GT6Natural Gas Fired Combustion TurbineNG84.5OP
GT7Natural Gas Fired Combustion TurbineNG84.5OP
GT8Natural Gas Fired Combustion TurbineNG84.5OP
GT1Natural Gas Fired Combustion TurbineNG81.3OP
GT2Natural Gas Fired Combustion TurbineNG81.3OP
GT3Natural Gas Fired Combustion TurbineNG81.3OP
GT4Natural Gas Fired Combustion TurbineNG81.3OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
3403
Sector
Electric Utility
Water source
Cumberland River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Gallatin (TN) power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Gallatin (TN)

Variation in the published months

Across 12 numeric monthly generation entries, 9 has the highest recorded value (504,938 MWh) and 4 the lowest (135,955 MWh). Their difference is 368,983 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 12 numeric rows displayed in this table, MW ranges from 81.3 (GT1, GT2, GT3) to 327.6 (3, 4). The difference is 246.3 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Conventional Steam Coal300.0225.0228.0108.0
2Conventional Steam Coal300.0225.0228.0108.0
3Conventional Steam Coal327.6263.0266.0130.0
4Conventional Steam Coal327.6263.0266.0130.0
GT1Natural Gas Fired Combustion Turbine81.371.588.710.0
GT2Natural Gas Fired Combustion Turbine81.371.588.710.0
GT3Natural Gas Fired Combustion Turbine81.371.588.710.0
GT4Natural Gas Fired Combustion Turbine81.371.588.710.0
GT5Natural Gas Fired Combustion Turbine84.573.493.757.0
GT6Natural Gas Fired Combustion Turbine84.573.493.757.0
GT7Natural Gas Fired Combustion Turbine84.573.493.757.0
GT8Natural Gas Fired Combustion Turbine84.573.493.757.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.