MWPowerPlantFacts

Data last collected:

EIA plant 7845

Brownsville · Haywood · TN

Lagoon Creek

Operated by Tennessee Valley Authority

Annual generation3,499,636 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextTennessee Valley AuthorityBalancing authority or NERC region

Published location

Where is Lagoon Creek?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

35.657800, -89.396400

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combustion Turbine1,020.8 MW represented
TechnologyNatural Gas Fired Combined Cycle604.4 MW represented

Grouped from this plant’s represented generator records. Use the TN plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1395,502
2325,623
3336,954
4262,108
5121,553
6260,702
7352,308
8390,409
9371,334
10342,296
1132,009
12308,838

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1395,502
2325,623
3336,954
4262,108
5121,553
6260,702
7352,308
8390,409
9371,334
10342,296
1132,009
12308,838

2024 monthly net generation

MonthNet generation
1395,502 MWh
2325,623 MWh
3336,954 MWh
4262,108 MWh
5121,553 MWh
6260,702 MWh
7352,308 MWh
8390,409 MWh
9371,334 MWh
10342,296 MWh
1132,009 MWh
12308,838 MWh

Operating generators

IDTechnologyFuelMWStatus
STG1Natural Gas Fired Combined CycleNG257.6OP
CTG1Natural Gas Fired Combined CycleNG173.4OP
CTG2Natural Gas Fired Combined CycleNG173.4OP
GT10Natural Gas Fired Combustion TurbineNG86.2OP
GT11Natural Gas Fired Combustion TurbineNG86.2OP
GT12Natural Gas Fired Combustion TurbineNG86.2OP
GT9Natural Gas Fired Combustion TurbineNG86.2OP
GT1Natural Gas Fired Combustion TurbineNG84.5OP
GT2Natural Gas Fired Combustion TurbineNG84.5OP
GT3Natural Gas Fired Combustion TurbineNG84.5OP
GT4Natural Gas Fired Combustion TurbineNG84.5OP
GT5Natural Gas Fired Combustion TurbineNG84.5OP
GT6Natural Gas Fired Combustion TurbineNG84.5OP
GT7Natural Gas Fired Combustion TurbineNG84.5OP
GT8Natural Gas Fired Combustion TurbineNG84.5OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
7845
Sector
Electric Utility
Water source
Memphis Sands Aquifer
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Lagoon Creek power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Lagoon Creek

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (395,502 MWh) and 11 the lowest (32,009 MWh). Their difference is 363,493 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 15 numeric rows displayed in this table, MW ranges from 84.5 (GT1, GT2, GT3) to 257.6 (STG1). The difference is 173.1 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CTG1Natural Gas Fired Combined Cycle173.4160.0190.078.2
CTG2Natural Gas Fired Combined Cycle173.4160.0190.078.2
GT1Natural Gas Fired Combustion Turbine84.573.994.360.0
GT10Natural Gas Fired Combustion Turbine86.272.792.860.0
GT11Natural Gas Fired Combustion Turbine86.272.792.860.0
GT12Natural Gas Fired Combustion Turbine86.272.792.860.0
GT2Natural Gas Fired Combustion Turbine84.573.994.360.0
GT3Natural Gas Fired Combustion Turbine84.573.994.360.0
GT4Natural Gas Fired Combustion Turbine84.573.994.360.0
GT5Natural Gas Fired Combustion Turbine84.573.994.360.0
GT6Natural Gas Fired Combustion Turbine84.573.994.360.0
GT7Natural Gas Fired Combustion Turbine84.573.994.360.0
GT8Natural Gas Fired Combustion Turbine84.573.994.360.0
GT9Natural Gas Fired Combustion Turbine86.272.792.860.0
STG1Natural Gas Fired Combined Cycle257.6205.0235.096.8

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check