MWPowerPlantFacts

Data last collected:

EIA plant 6433

Metaline · Pend Oreille · WA

Boundary

Operated by City of Seattle - (WA)

Annual generation3,020,283 MWhSum of represented EIA-923 rows
Fuel codesWATCodes retained from EIA records
Grid contextSeattle City LightBalancing authority or NERC region

Published location

Where is Boundary?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

48.987111, -117.347847

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Hydroelectric1,159.7 MW represented

Grouped from this plant’s represented generator records. Use the WA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1220,146
2242,583
3286,878
4249,073
5401,290
6434,249
7261,164
8135,421
9138,906
10269,165
11199,563
12181,845

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1220,146
2242,583
3286,878
4249,073
5401,290
6434,249
7261,164
8135,421
9138,906
10269,165
11199,563
12181,845

2024 monthly net generation

MonthNet generation
1220,146 MWh
2242,583 MWh
3286,878 MWh
4249,073 MWh
5401,290 MWh
6434,249 MWh
7261,164 MWh
8135,421 MWh
9138,906 MWh
10269,165 MWh
11199,563 MWh
12181,845 MWh

Operating generators

IDTechnologyFuelMWStatus
55Conventional HydroelectricWAT239.4OP
56Conventional HydroelectricWAT239.4OP
51Conventional HydroelectricWAT180.5OP
54Conventional HydroelectricWAT180.5OP
52Conventional HydroelectricWAT161.5OP
53Conventional HydroelectricWAT158.4OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
6433
Sector
Electric Utility
Water source
Pend Oreille River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Boundary power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Boundary

Variation in the published months

Across 12 numeric monthly generation entries, 6 has the highest recorded value (434,249 MWh) and 8 the lowest (135,421 MWh). Their difference is 298,828 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 6 numeric rows displayed in this table, MW ranges from 158.4 (53) to 239.4 (55, 56). The difference is 81 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
51Conventional Hydroelectric180.5180.5180.520.0
52Conventional Hydroelectric161.5161.5161.520.0
53Conventional Hydroelectric158.4158.4158.420.0
54Conventional Hydroelectric180.5180.5180.520.0
55Conventional Hydroelectric239.4232.0232.05.0
56Conventional Hydroelectric239.4232.0232.05.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check