MWPowerPlantFacts

Data last collected:

EIA plant 7302

Bartow · Polk · FL

Hines Energy Complex

Operated by Duke Energy Florida, LLC

Annual generation12,354,258 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextProgress Energy FloridaBalancing authority or NERC region

Published location

Where is Hines Energy Complex?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

27.788215, -81.869983

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle2,266.3 MW represented

Grouped from this plant’s represented generator records. Use the FL plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1642,028
2695,586
3734,621
41,010,567
51,256,891
61,169,851
71,276,142
81,304,473
91,208,444
101,151,021
111,109,570
12795,064

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1642,028
2695,586
3734,621
41,010,567
51,256,891
61,169,851
71,276,142
81,304,473
91,208,444
101,151,021
111,109,570
12795,064

2024 monthly net generation

MonthNet generation
1642,028 MWh
2695,586 MWh
3734,621 MWh
41,010,567 MWh
51,256,891 MWh
61,169,851 MWh
71,276,142 MWh
81,304,473 MWh
91,208,444 MWh
101,151,021 MWh
111,109,570 MWh
12795,064 MWh

Operating generators

IDTechnologyFuelMWStatus
4STNatural Gas Fired Combined CycleNG212.5OP
3STNatural Gas Fired Combined CycleNG204OP
1STNatural Gas Fired Combined CycleNG199.7OP
4GTNatural Gas Fired Combined CycleNG199OP
4GT2Natural Gas Fired Combined CycleNG199OP
2STNatural Gas Fired Combined CycleNG191.3OP
2GTNatural Gas Fired Combined CycleNG178.5OP
2GT2Natural Gas Fired Combined CycleNG178.5OP
3GTNatural Gas Fired Combined CycleNG178.5OP
3GT2Natural Gas Fired Combined CycleNG178.5OP
1GTNatural Gas Fired Combined CycleNG173.4OP
1GT2Natural Gas Fired Combined CycleNG173.4OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
7302
Sector
Electric Utility
Water source
Cooling Ponds
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Hines Energy Complex power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Hines Energy Complex

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (1,304,473 MWh) and 1 the lowest (642,028 MWh). Their difference is 662,445 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 12 numeric rows displayed in this table, MW ranges from 173.4 (1GT, 1GT2) to 212.5 (4ST). The difference is 39.1 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1GTNatural Gas Fired Combined Cycle173.4167.0174.0167.0
1GT2Natural Gas Fired Combined Cycle173.4167.0177.0167.0
1STNatural Gas Fired Combined Cycle199.7167.0170.0162.0
2GTNatural Gas Fired Combined Cycle178.5176.0179.0176.0
2GT2Natural Gas Fired Combined Cycle178.5174.0183.0174.0
2STNatural Gas Fired Combined Cycle191.3182.0187.0182.0
3GTNatural Gas Fired Combined Cycle178.5171.0175.0171.0
3GT2Natural Gas Fired Combined Cycle178.5176.0177.0176.0
3STNatural Gas Fired Combined Cycle204.0176.0183.0176.0
4GTNatural Gas Fired Combined Cycle199.0188.0179.0171.0
4GT2Natural Gas Fired Combined Cycle199.0176.0179.0176.0
4STNatural Gas Fired Combined Cycle212.5180.0186.0178.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check