MWPowerPlantFacts

Data last collected:

EIA plant 56407

Loxahatchee · Palm Beach · FL

West County Energy Center

Operated by Florida Power & Light Co

Annual generation19,815,239 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextFlorida Power & Light CompanyBalancing authority or NERC region

Published location

Where is West County Energy Center?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

26.698600, -80.374700

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle4,263 MW represented

Grouped from this plant’s represented generator records. Use the FL plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,422,421
2840,279
31,709,505
41,451,805.01
51,841,544
61,872,883.98
72,251,116
82,157,650
92,043,743.03
101,807,782.03
111,491,265.99
12925,244

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,422,421
2840,279
31,709,505
41,451,805.01
51,841,544
61,872,883.98
72,251,116
82,157,650
92,043,743.03
101,807,782.03
111,491,265.99
12925,244

2024 monthly net generation

MonthNet generation
11,422,421 MWh
2840,279 MWh
31,709,505 MWh
41,451,805 MWh
51,841,544 MWh
61,872,884 MWh
72,251,116 MWh
82,157,650 MWh
92,043,743 MWh
101,807,782 MWh
111,491,266 MWh
12925,244 MWh

Operating generators

IDTechnologyFuelMWStatus
1STNatural Gas Fired Combined CycleNG527OP
2STNatural Gas Fired Combined CycleNG527OP
3STNatural Gas Fired Combined CycleNG527OP
1ANatural Gas Fired Combined CycleNG298OP
1BNatural Gas Fired Combined CycleNG298OP
1CNatural Gas Fired Combined CycleNG298OP
2ANatural Gas Fired Combined CycleNG298OP
2BNatural Gas Fired Combined CycleNG298OP
2CNatural Gas Fired Combined CycleNG298OP
3ANatural Gas Fired Combined CycleNG298OP
3BNatural Gas Fired Combined CycleNG298OP
3CNatural Gas Fired Combined CycleNG298OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
56407
Sector
Electric Utility
Water source
Village of Wellington, Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right West County Energy Center power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at West County Energy Center

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (2,251,116 MWh) and 2 the lowest (840,279 MWh). Their difference is 1,410,837 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 12 numeric rows displayed in this table, MW ranges from 298 (1A, 1B, 1C) to 527 (1ST, 2ST, 3ST). The difference is 229 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1ANatural Gas Fired Combined Cycle298.0257.6295.6232.0
1BNatural Gas Fired Combined Cycle298.0257.6295.6232.0
1CNatural Gas Fired Combined Cycle298.0257.6295.6232.0
1STNatural Gas Fired Combined Cycle527.0486.2482.2350.0
2ANatural Gas Fired Combined Cycle298.0257.7295.6232.0
2BNatural Gas Fired Combined Cycle298.0257.7295.6232.0
2CNatural Gas Fired Combined Cycle298.0257.7295.6232.0
2STNatural Gas Fired Combined Cycle527.0485.9482.2350.0
3ANatural Gas Fired Combined Cycle298.0257.6295.6232.0
3BNatural Gas Fired Combined Cycle298.0257.6295.6244.0
3CNatural Gas Fired Combined Cycle298.0257.6295.6232.0
3STNatural Gas Fired Combined Cycle527.0486.2482.2350.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check